| Maximum Impact Pressure | 42Mpa |
|---|---|
| Piston Pump | Flow Rate 18.78LPM, |
| Maximum Pressure | 50Mpa |
| Moto | 18.5KW-4 Motor |
| Pressure Sensors | 0~60MPa,0.25%FS |
| Application | Impulse Testing Of Cylinders, Piston Pump Motors, Valves, Metal Housings, Hoses Or Tube Assemblies |
|---|---|
| Voltage | 380V AC 50Hz |
| Air Source | 0.7MPa |
| Control Mode | Hydraulic Servo Control |
| Control &Collection | PLC Control, Proportional Valve Loading, Computer Acquisition |
| Operating Noise | Not Higher Than 95 Decibels |
|---|---|
| Reciprocating Stroke | Up To 400m (stroke Adjustable) |
| Motor Power | 7.5KW |
| Pressure Measurement Accuracy | ≦±0.25% |
| Test Oil Temperature | Room Temperature -115°C |
| Drive Cylinder Speed Accuracy | ≦±10% |
|---|---|
| Warranty | 1 Year. 24hr Online Technical Guidanceyear. 24hr Online Technical Guidance |
| Oil Temperature Control Accuracy | ±5°C |
| Speed | 0.05-0.4m/s |
| Pressure Measurement Accuracy | ≦±0.25% |
| Rated Pressure | 40 Mpa |
|---|---|
| Rated Flow Rate | 150 L/min |
| Flowmeter Specifications (Large) | 1~250 L/min |
| Flowmeter Specifications (Small) | 0.02~4 L/min |
| Pressure Sensor Range | 0-60Mpa (oil Supply, Working Cavity), 0-10Mpa (oil Return) |
| Cavity Pressure | 1.5~42MPa |
|---|---|
| Test Oil Temperature | Room Temperature -115°C; |
| Oil Temperature Control Accuracy | ±5°C |
| Reciprocating Stroke | Up To 400m (stroke Adjustable); |
| Reciprocating Speed | 0.05-0.4m/s; |
| Rated Pressure | 40 Mpa |
|---|---|
| Rated Flow Rate | 150 L/min |
| Flowmeter Specifications (Large) | 1~250 L/min |
| Flowmeter Specifications (Small) | 0.02~4 L/min |
| Pressure Sensor Range | 0-60Mpa (oil Supply, Working Cavity), 0-10Mpa (oil Return) |
| Rated Pressure | 40 Mpa |
|---|---|
| Rated Flow Rate | 150 L/min |
| Flowmeter Specifications (Large) | 1~250 L/min |
| Flowmeter Specifications (Small) | 0.02~4 L/min |
| Pressure Sensor Range | 0-60Mpa (oil Supply, Working Cavity), 0-10Mpa (oil Return) |
| Safety Features | Emergency Stop Button, Overload Protection |
|---|---|
| Model | HC-100 |
| Test Load Range | 0-10 Tons |
| Max Stroke | 1000 Mm |
| Max Load Capacity | 10 Tons |
| Fuel Tank Volume | 2,000L |
|---|---|
| Circulatory System | Motor: 7.5KW-4 Progressive Cavity Pump: 160L/min Maximum Pressure: 1.5MPa |
| Pumping System | Motor: 1.5KW-4*2 Progressive Cavity Pump: 24L/min*2 |
| Cooling Method | Water Cooling, Automatic Temperature Control |
| Control &Collection | PLC Control, Proportional Valve Loading, Computer Acquisition |